subscribe
e-newsletter
digital edition
reader service
advertise
    Subscribe to GreenSource the magazine
of sustainable design: $19.95 for one year
print this article   |    e-mail this article   |    comment     

The Passive Solar Primer: Sustainable Architecture

By David Wright, AIA. Atglen, Pennsylvania: Schiffer Publishing, 2008, 273 pages, $29.99.

Reviewed by David Sokol

The Passive Solar Primer certainly has its hippie moments. There are the overt political statements, only passing references to computer modeling, and “The Electric Company” typefaces, not to mention the illustrations seemingly ripped from the pages of a vintage Up With People brochure. But can you blame author David Wright? The author-architect is the real thing, having built a two-story adobe house in Santa Fe in long-ago 1973 and a similarly climate-sensitive, much-publicized residence in Sea Ranch, California later that decade.

The Passive Solar Primer: Sustainable Architecture
Image courtesy Schiffer Publishing
David Wright, AIA, The Passive Solar Primer: Sustainable Architecture, 2008
Rate this project:
Based on what you have seen and read about this project, how would you grade it? Use the stars below to indicate your assessment, five stars being the highest rating.
----- Advertising -----

This throwback is more relevant than ever. So is his primer. The Passive Solar Primer covers all the bases of heat loss and gain, thermal storage, and engagement with landscape for single-family homes. Once you get past the anachronistic flaws, you’ll find Wright’s pointers—such as his discussion of mean radiant temperature or the unique ability of local materials to accommodate local climates—to be far more sophisticated than the appearance of the book, too. A favorite feature: The chapter entitled “Rules of Thumb,” which divides the continental United States into a series of regions, with lists of must-do rules for achieving passive solar performance in that area. “For economy of construction, size south glazing in the range of 10 percent to 15 percent of the floor area” in Minnesota, for example, while homes in New Mexico should sport “2 to 8 inches thick walls, 4 to 6 inches thick on floors” for thermal mass.

Reader Comments:

We welcome comments from all points of view. Off-topic or abusive comments, however, will be removed at the editors’ discretion.

----- Advertising -----
----- Advertising -----
McGraw-Hill GreenSource Series
The Greenbuild Blog
Dispatches from the 2009 Greenbuild conference in Phoenix >>
GREENSOURCE MAGAZINE
Greenbuild Photo Gallery


View all photos >>

GreenSource Selects: Blogs

View all blogs >>
Recent Forum Discussions

View all forum discusions >>